#ExistMethodology>
| Methodology: |
Inductively Coupled Plasma-Mass Spectrometry
|
*ExistMethodology>
#ExistPerformed>
| Performed: |
Varies
|
*ExistPerformed>
#ExistReported>
| Reported: |
7-14 days
|
*ExistReported>
#ExistSpecRequirements>
| Specimen Required: |
#ExistPATIENTPREP>Patient Prep: Patients that have used a Grecian® Formula product cannot have lead testing performed on hair as those products contain lead.
*ExistPATIENTPREP>
#ExistCollect>Collect: From the back of the head gather a lock of hair the width of a pencil. Cut hair near scalp, cutting at least 3 inches. Do not apply tape to hair. Also acceptable: underarm, pubic, chest, beard, or mustache hair.
*ExistCollect>
#ExistSPECIMENPREPARATION>Specimen Preparation: Transfer 0.5 g hair (typically this is the length of an index finger (3 inches) and the width of a pencil) to a plastic, metal-free container. (Min: 0.1 g) Indicate source of hair on outside of container.
*ExistSPECIMENPREPARATION>
#ExistSPECTRANSPORT>Storage/Transport Temperature: Room temperature. Also acceptable: Refrigerated or frozen.
*ExistSPECTRANSPORT>
#ExistConditions>Unacceptable Conditions: Beard trimmings or razor clippings.
*ExistConditions>
#ExistStability>Stability (collection to initiation of testing): If the specimen is collected and stored in the appropriate container, the trace element values do not change with time.
*ExistStability>
|
*ExistSpecRequirements>
|
|